Purpose
The purpose of this article is to provide instructions for configuring Tesoro & Sanofi RFID badge readers used with ReadyTouch kiosks.
Tesoro
- Download and install the RFIDeas Config Utility.
- Once installed, go to the top right and click on the 3 lines icon, then select Device, then click Reset to Defaults.
- On the left-hand side, select the Format tab.
- On the top, change Configuration 1 to Configuration 2.
- Configuration 2 should be set to iClass ID by default.
- Configuration 2 should be set to iClass ID by default.
- In the Format tab, select Data Format and change the ID field Bit Count from 16 to 20.
- In the same Format tab, click the Write Settings button in the top-left corner.
- Lastly, test the badge in the test area.
Sanofi
- Download and install the pcProx Config Utility.
- Connect the RFIDeas reader to a USB port.
- Inside the pcProx Config Utility, click Connect.
- Choose File → Open, then navigate to and select the hwg+ file, then click Open.
- This file can be downloaded from the bottom of the Table of Contents section on the left-hand side of this article.
- The below is an example of the configuration settings:
- Click Write Active.
- When the write is complete, click Disconnect.